Detalhe da pesquisa
1.
Influence of exposure to climate-related hazards in the phenotypic expression of primary Sjögren's syndrome.
Clin Exp Rheumatol
; 41(12): 2437-2447, 2023 12.
Artigo
em Inglês
| MEDLINE | ID: mdl-38019164
2.
Childhood-onset of primary Sjögren's syndrome: phenotypic characterization at diagnosis of 158 children.
Rheumatology (Oxford)
; 60(10): 4558-4567, 2021 10 02.
Artigo
em Inglês
| MEDLINE | ID: mdl-33493333
3.
Influence of the age at diagnosis in the disease expression of primary Sjögren syndrome. Analysis of 12,753 patients from the Sjögren Big Data Consortium.
Clin Exp Rheumatol
; 39 Suppl 133(6): 166-174, 2021.
Artigo
em Inglês
| MEDLINE | ID: mdl-34919044
4.
Clinical Evaluation of Implant-Supported Removable Partial Dentures With a Stress-Breaking Attachment.
Implant Dent
; 26(4): 516-523, 2017 Aug.
Artigo
em Inglês
| MEDLINE | ID: mdl-28375862
5.
Occlusal contact of fixed implant prostheses using functional bite impression technique.
Implant Dent
; 24(1): 42-6, 2015 Feb.
Artigo
em Inglês
| MEDLINE | ID: mdl-25379661
6.
In vitro assessment of mandibular single/two implant-retained overdentures using stress-breaking attachments.
Implant Dent
; 23(4): 456-62, 2014 Aug.
Artigo
em Inglês
| MEDLINE | ID: mdl-25033343
7.
Clinical application of an intraoral scanner and CAD/CAM system for a Kennedy class I partially edentulous patient.
J Oral Sci
; 64(1): 109-111, 2022 Jan 19.
Artigo
em Inglês
| MEDLINE | ID: mdl-34937814
8.
Laboratory efficiency of additive manufacturing for removable denture frameworks: A literature-based review.
Dent Mater J
; 40(2): 265-271, 2021 Mar 31.
Artigo
em Inglês
| MEDLINE | ID: mdl-33361665
9.
Influence of marginal bone resorption on two mini implant-retained mandibular overdenture: An in vitro study.
J Adv Prosthodont
; 13(1): 55-64, 2021 Feb.
Artigo
em Inglês
| MEDLINE | ID: mdl-33747395
10.
Effect of implant support on distal-extension removable partial dentures: in vivo assessment.
Int J Oral Maxillofac Implants
; 23(6): 1095-101, 2008.
Artigo
em Inglês
| MEDLINE | ID: mdl-19216279
11.
Titanium removable denture based on a one-metal rehabilitation concept.
Dent Mater J
; 36(5): 517-523, 2017 Sep 26.
Artigo
em Inglês
| MEDLINE | ID: mdl-28835600
12.
Retentive force of O-ring attachment to use Immediate Provisional Implant (IPI)-retained overdenture.
Eur J Prosthodont Restor Dent
; 13(4): 147-9, 2005 Dec.
Artigo
em Inglês
| MEDLINE | ID: mdl-16411569
13.
Fixation of magnet assembly to denture base using alternative resins.
Dent Mater J
; 34(3): 364-70, 2015.
Artigo
em Inglês
| MEDLINE | ID: mdl-25904166
14.
Fabrication of crown restoration retrofitting to existing clasps using CAD/CAM: fitness accuracy and retentive force.
J Prosthodont Res
; 59(2): 136-43, 2015 Apr.
Artigo
em Inglês
| MEDLINE | ID: mdl-25662150
15.
Pressure distribution of implant-supported removable partial dentures with stress-breaking attachments.
J Prosthodont Res
; 58(2): 115-20, 2014 Apr.
Artigo
em Inglês
| MEDLINE | ID: mdl-24636367
16.
Clinical application of stress-breaking ball attachment for implant overdenture.
J Prosthodont Res
; 57(2): 140-4, 2013 Apr.
Artigo
em Inglês
| MEDLINE | ID: mdl-23490449
17.
Effect of implant support on mandibular distal extension removable partial dentures: relationship between denture supporting area and stress distribution.
J Prosthodont Res
; 57(2): 109-12, 2013 Apr.
Artigo
em Inglês
| MEDLINE | ID: mdl-23582267
18.
Fabrication of fixed implant prostheses using function bite impression technique (FBI technique).
J Prosthodont Res
; 56(4): 293-6, 2012 Oct.
Artigo
em Inglês
| MEDLINE | ID: mdl-22609223
19.
Long-term clinical evaluation of implant over denture.
J Prosthodont Res
; 56(1): 32-6, 2012 Jan.
Artigo
em Inglês
| MEDLINE | ID: mdl-21705295
20.
Nifedipine-induced gingival hypertrophy.
Intern Med
; 51(1): 121, 2012.
Artigo
em Inglês
| MEDLINE | ID: mdl-22214637